WINTERHALTER SOFTWARE DOWNLOAD
Winterhalter constantly strives to improve its products and periodically provides updates for the software. To keep your machine running smoothly and delivering the best attended results, update the software on a regular basis.
Important Note
From 6 January 2025, the following software packages can only be installed if the date on the machine is set to a date before 6 January 2025.
• UC V02: UC000093
• PT V02: PT000055
• CTR: CTR000040
The reason for this is that the signature of the software packages will no longer be valid from 6 January 2025. However, as the signature is only checked during installation, the current date can be set again after installation.
In order to install higher software packages, the software package listed above must always be installed first if a lower software version is installed on the machine. The software packages listed above are therefore permanently available.
Current Update
RootFS version: 4.3
Frequency inverter version: V48
HMI (app) version: 3.1.7
Control unit version: 1.2.8
The update contains the following changes:
- Implementation of the AI EcoPilot feature.
This involves the machine-side preparation of a new function. The feature will be activated following the announcement via a product info and can only be used with networked CONNECTED WASH machines. - Further improvements regarding display performance and usability.
- Improved text rendering through the introduction of hyphenation.
- Door status (open/closed) is transmitted to the CONNECTED WASH dashboard.
- If the CAN bus data line is defective, the error message "Firmware verification failed" will appear.
- Entries in the hygiene logbook, operating data logger, and error log are no longer obscured by the scroll bar.
Please note:
- The software update can only be installed if at least software version UC000093 is installed on the machine.
- If this is not the case, set the date on the machine to 05/01/2025 and then install software update UC000093.
- Then set the current date and install the latest software update.
RootFS version: 4.3
Frequency inverter version STM32: 20
Frequency inverter version ATSAM: 22
HMI (app) version: 3.1.7
Control unit version: 1.3.5
Automatic hood software version: 1.2.2
Power unit version: 4.0.0
The update contains the following changes:
- Implementation of the AI EcoPilot feature.
This involves the machine-side preparation of a new function. The feature will be activated following the announcement via a product info and can only be used with networked CONNECTED WASH machines. - Further improvements regarding display performance and usability.
- Improved text rendering through the introduction of hyphenation.
- Hood status (open/closed) is transmitted to the CONNECTED WASH dashboard.
- If the CAN bus data line is defective, the error message "Firmware verification failed" will appear.
- Entries in the hygiene logbook, operating data logger, and error log are no longer obscured by the scroll bar.
Please note:
- The software update can only be installed if at least software version PT000055 is installed on the machine.
- If this is not the case, set the date on the machine to 05/01/2025 and then install software update PT000055.
- Then set the current date and install the latest software update.
RootFS version: 4.3
Frequency inverter (rack transport) version: 48
Frequency inverter (rinse booster pump) version: 48
HMI (app) version: 3.1.7
Control unit version: 1.0.12
Power unit version: 4.0.0
The update contains the following changes:
- Further improvements regarding display performance and usability.
- Improved text rendering through the introduction of hyphenation.
- Door status (open/closed) is transmitted to the CONNECTED WASH dashboard.
- If the CAN bus data line is defective, the error message "Firmware verification failed" will appear.
- Entries in the hygiene logbook, operating data logger, and error log are no longer obscured by the scroll bar.
Please note:
- The software update can only be installed if at least software version CTR000040 is installed on the machine.
- If this is not the case, set the date on the machine to 05/01/2025 and then install software update CTR000040.
- Then set the current date and install the latest software update.
RootFS version: 4.3
HMI (app) version: 3.1.7
Frequency inverter version: V73
Control unit version: 1.4.5
Control unit mini version: 1.5.0
Conductivity measurement unit version: 1.0.0
Quick-start button version: 1.1.4
The update contains the following changes:
- Further improvements regarding display performance and usability.
- Improved text rendering through the introduction of hyphenation.
- If the hardware detection encounters an error during display replacement, the message "Software incompatible" will now include a list of affected components.
- Correct display of CAN component versions.
- Changing the rinse water quantity in the "Sinner Circle" menu occasionally caused the HMI to crash (the display went black). This bug has been fixed.
- The wash programme mode (Hygiene, Speed, HighTemp, Container) is correctly transmitted to the CONNECTED WASH Dashboard.
- Entries in the hygiene log-book, operating data logger, and error log are no longer obscured by the scroll bar.
- Parameter changes are now displayed with date and time stamps.
- As long as a lack of detergent persists, the error message must be acknowledged before starting any wash cycle.
- The pictogram library for wash programmes now includes the "Leaf Pictogram" for programmes with special settings. Selecting the pictogram does not yet modify programme settings.
- If a CONNECTED WASH machine remains offline for more than 5 days, a notification appears on the display.
- Expanded country list for registering a CONNECTED WASH machine.
- In the address entry menu, the address field and phone number remain blank if a country other than Germany is selected during menu-driven setup.
- For multi-line text entries (e.g., addresses), the cursor can now be placed directly at the position requiring correction.
- The hygiene logbook and data logger now only display errors and events relevant to the specific machine when filtering.
- The 100% water exchange is now correctly saved in the hygiene logbook and transmitted to the CONNECTED WASH Dashboard.
RootFS version: 4.3
Frequency inverter (rack transport) version: 48
Frequency inverter (rinse booster pump) version: 48
HMI (app) version: 3.0.2
Control unit version: 1.0.9
Power unit version: 2.0.0
The update contains the following changes:
- Optimization and bug fixes
RootFS version: 4.3
Frequency inverter version STM32: 20
Frequency inverter version ATSAM: 22
HMI (app) version: 3.0.2
Control unit version: 1.3.2
Automatic hood software version: 1.2.0
Power unit version: 4.0.0
The update contains the following changes:
- Optimization and bug fixes
RootFS version: 4.3
Frequency inverter version: V48
HMI (app) version: 3.0.2
Control unit version: 1.2.4
The update contains the following changes:
- Optimization and bug fixes